🏢 What Areas Can Be Omitted from Sprinkler Protection According to NFPA 13?

Views in the last 30 days: 37

Estimated read time: 3 minute(s)

✨ First Things First: What Is “Sprinkler Omission”?

In simple words, “sprinkler omission” means NFPA 13 allows you to skip installing a sprinkler in certain spaces where the fire risk is very low.

Construction Material Icon

Construction Material

Non-combustible materials reduce fire spread.

Access to Space Icon

Access to Space

Spaces rarely accessed can qualify for omission.

Contents Icon

Contents Inside

Empty shafts or mechanical spaces often qualify.

Fire Behavior Icon

Fire Behavior

Likelihood and intensity of fire is very low.

🔥 Where Can Sprinklers Be Omitted According to NFPA 13?

Here are the most common spaces where NFPA 13 allows sprinkler omission – based on fire risk, space access, and construction material. Hover or scroll to explore each one!

✨ Concealed Spaces Without High Fire Risk

Noncombustible or limited-combustible construction, no human access, and minimal combustibles.

  • Closed ceilings with no attic access
  • Air return slits
Ref: NFPA 13 §9.2.1.1 & §9.2.1.2

🌳 Tiny Concealed Spaces

Between studs or joists, <6 inches wide, no occupancy or combustible storage.

💚 Spaces Filled with Noncombustible Insulation

Like mineral wool, fully packed, with a 2″ air gap allowed at the top.

🏢 Above Small Compartments

If the space below is ≤ 55 ft² (5.1 m²)

🛏️ Vertical Pipe Chases

Shafts under 10 ft² (0.9 m²) with no ignition sources. Firestop between floors is essential!

🏋️ Closets and Pantries

Inside dwellings (like apartments), under 24 ft², with noncombustible or limited-combustible enclosures.

⚡️ Electrical Equipment Rooms

  • Dedicated to electrical use
  • Non-flammable fluids
  • 2-hour fire-rated walls
  • No storage allowed

(Makes sense – no water near live circuits!)

💼 Built-In Cabinets & Furniture

Wardrobes, displays, and enclosed cabinetry may not need sprinklers inside.

🏦 Open Parking Structures

Sprinklers may be skipped if the structure is noncombustible and open-air ventilated.

🕯️ Special Construction Types

  • Cloud ceilings
  • Vertical shafts & stair towers
  • Revolving doors, skylights
See NFPA 13 §9.2.7–9.3.16

✅ Can This Space Be Omitted from Sprinklers?

Answer the checklist below and see if your space qualifies for omission under NFPA 13!

📊 Quick Summary Table

Here’s a fast-reference table for common areas where sprinkler systems may be omitted under NFPA 13:

Area Type Can Sprinklers Be Omitted? Conditions
Concealed noncombustible spaces Yes No access, minimal combustibles
Small pipe chases Yes <10 ft², no ignition sources
Closets in dwellings Yes <24 ft², noncombustible finishes
Electrical rooms Yes 2-hour fire-rated walls, no storage
Furniture/cabinets Yes No occupancy inside