✨ First Things First: What Is “Sprinkler Omission”?
In simple words, “sprinkler omission” means NFPA 13 allows you to skip installing a sprinkler in certain spaces where the fire risk is very low.

Construction Material
Non-combustible materials reduce fire spread.

Access to Space
Spaces rarely accessed can qualify for omission.

Contents Inside
Empty shafts or mechanical spaces often qualify.

Fire Behavior
Likelihood and intensity of fire is very low.
🔥 Where Can Sprinklers Be Omitted According to NFPA 13?
Here are the most common spaces where NFPA 13 allows sprinkler omission – based on fire risk, space access, and construction material. Hover or scroll to explore each one!
✨ Concealed Spaces Without High Fire Risk
Noncombustible or limited-combustible construction, no human access, and minimal combustibles.
- Closed ceilings with no attic access
- Air return slits
🌳 Tiny Concealed Spaces
Between studs or joists, <6 inches wide, no occupancy or combustible storage.
💚 Spaces Filled with Noncombustible Insulation
Like mineral wool, fully packed, with a 2″ air gap allowed at the top.
🏢 Above Small Compartments
If the space below is ≤ 55 ft² (5.1 m²)
🛏️ Vertical Pipe Chases
Shafts under 10 ft² (0.9 m²) with no ignition sources. Firestop between floors is essential!
🏋️ Closets and Pantries
Inside dwellings (like apartments), under 24 ft², with noncombustible or limited-combustible enclosures.
⚡️ Electrical Equipment Rooms
- Dedicated to electrical use
- Non-flammable fluids
- 2-hour fire-rated walls
- No storage allowed
(Makes sense – no water near live circuits!)
💼 Built-In Cabinets & Furniture
Wardrobes, displays, and enclosed cabinetry may not need sprinklers inside.
🏦 Open Parking Structures
Sprinklers may be skipped if the structure is noncombustible and open-air ventilated.
🕯️ Special Construction Types
- Cloud ceilings
- Vertical shafts & stair towers
- Revolving doors, skylights
✅ Can This Space Be Omitted from Sprinklers?
Answer the checklist below and see if your space qualifies for omission under NFPA 13!
📊 Quick Summary Table
Here’s a fast-reference table for common areas where sprinkler systems may be omitted under NFPA 13:
Area Type | Can Sprinklers Be Omitted? | Conditions |
---|---|---|
Concealed noncombustible spaces | Yes | No access, minimal combustibles |
Small pipe chases | Yes | <10 ft², no ignition sources |
Closets in dwellings | Yes | <24 ft², noncombustible finishes |
Electrical rooms | Yes | 2-hour fire-rated walls, no storage |
Furniture/cabinets | Yes | No occupancy inside |