Inputs
Segments (add rooms/blocks/households)
Design Parameters
IS 2470 recommends 24–48 h (3.4.4).
Auto-fills from standard (e.g., IS: ~77 L/p·y).
Auto-fills from standard/guide.
Min 1.0 m liquid depth per IS (3.4.5.1).
IS suggests L = 2–4 × W (3.4.5).
>20 users usually 3 chambers (practice).
Editable detailing assumption.
Costing (editable unit rates)
Auto from selected market (editable).
Highly variable; edit to local.
Calculated Results
ItemValueNotes
Cost breakdown
Methodology & Formulas (collapsible)

Hydraulic sizing
Daily sewage flow: Q = Σ(occupants × per-capita discharge).
Working liquid volume: Vliq = Q × (t/24) where t is detention (h).
Sludge storage: Vs = (occupants × sludge_rate × years) / 1000 (if rate in L/p·y).
Total working volume: Vw = Vliq + Vs.
Plan area: A = Vw / Dliq.
With L:W = r, internal W = √(A / r), internal L = r × W.
Internal total depth: D = Dliq + freeboard.

Reverse mode
Given internal L, W, Dliq: Vw = L×W×Dliq. Net liquid for flow = VwVs.
Q = 24 × (Net liquid) / t → People = Q / per-capita discharge.

Materials (approx.)
External L,W = internal + 2× wall_thk; Ext. depth = D + base_thk.
RCC volume ≈ base slab + top slab + walls + partitions.
Rebar mass = RCC × (kg per m³). Excavation ≈ (ext L+0.6)×(ext W+0.6)×(ext depth + 0.2).

Values derived from selected Standard (user must verify).

Sources & Defaults (highlighted)

Standards / Guides:

  • IS 2470 (Part 1) – detention 24–48 h; min width 750 mm; liquid depth ≥1.0 m; sludge volume ≈0.00021 m³/p·d. PDF
  • CPHEEO Manual – typical sewerage assumptions; sludge ~67 L/p·year (3-yr cycle context). PDF Advisory
  • US EPA OWTS Manual – 24 h minimum detention at pumped condition; sludge/scum accumulation context. EPA Manual
  • UK Approved Document H / EN 12566 – septic tanks and small sewage treatment systems context (flows widely ~150 L/p·d typical).

Unit rates (editable defaults):

  • India – Concrete ~₹6000/m³ (typical supplier range).
  • US – Ready-mix ~$166/yd³ (~$217/m³ midpoint).
  • UK – Ready-mix ~£135–£150/m³ (C20–C40).
  • India – Rebar ~₹76/kg; US ~$1.6/kg midpoint; UK ~£0.60/kg.
  • 110 mm / 4″ PVC: IN ~₹100/m; US ~$2.63/ft; UK ~£4/m. Access lids vary by market.
How to use
  1. Pick Units and a Standard. Defaults auto-populate detention time, per-capita discharge, and sludge rate (you can edit).
  2. Add Segments (e.g., “Main house”, “Annexe”). Each segment stores people count and per-capita discharge.
  3. Set design parameters (depth, L:W, chambers). Press Calculate.
  4. Adjust unit rates for your market (IN/US/UK presets fill in sensible ranges). Costs update instantly.
  5. Use Reverse mode to test “given tank size → how many people does it support?”.
  6. Click Generate HTML Report to download/print a standalone, branded report with KPIs, tables, formulas, and assumptions.

Septic Tank Calculator — What It Does, How It Works, and a Full Worked Example

A practical tool for right-sizing septic tanks with **standards presets**, **SI/Imperial toggle**, **multi-segment occupants**, and **editable India/US/UK cost rates**. Generate a clean HTML report with KPIs, assumptions and a detailed table in one click.

✨ Presets: IS 2470 / CPHEEO / US EPA / UK AD-H
🧮 Forward & Reverse sizing • Canvas cost chart • Report

What this calculator is for

It helps you size a septic tank and estimate key **components & costs**. Enter your occupants (or daily flow), choose a design standard, and the tool computes:

  • Working volume = detention (clarification) + sludge storage for your desludging interval.
  • Internal dimensions from your chosen depth and L:W ratio, plus external dimensions with wall/top/base thicknesses.
  • Materials: RCC volume, rebar mass, excavation, pipes, covers — followed by a cost breakdown for 🇮🇳 India, 🇺🇸 US, or 🇬🇧 UK (editable).
Standards at a glance (auto-defaults)

Pick a standard to auto-fill detention time, per-capita discharge, and sludge rate. A green note appears in the widget with: “Values derived from <Standard> (user must verify).”

  • IS 2470 (Part 1): 24–48 h detention, liquid depth ≥ 1.0 m, min width 750 mm, sludge ≈ 0.00021 m³/p·d IS 2470 clause refs (see PDF link in the widget).
  • CPHEEO Manual (India): domestic ~108 lpcd; sludge ~67 L/p·year context CPHEEO.
  • US EPA OWTS: typical 75 gpd/person; 24 h detention; sludge accumulation guidance EPA.
  • UK AD-H / EN 12566: ~150 lpcd typical flows; small package systems context AD-H.

How the calculator works (in plain English)

The math follows the usual septic design steps, shown inside the widget’s Methodology accordion. In short:

  1. Daily flow \(Q\) = Σ(people × per-capita discharge × peak factor).
  2. Liquid volume \(V_\mathrm{liq}\) = \(Q × \frac{t}{24}\) where \(t\) is detention time (hours).
  3. Sludge storage \(V_\mathrm{s}\) = \(\frac{\text{people} × \text{sludge\_rate} × \text{years}}{1000}\) (if sludge rate is in L/person·year).
  4. Total working volume \(V_\mathrm{w}\) = \(V_\mathrm{liq} + V_\mathrm{s}\).
  5. With liquid depth \(D_\mathrm{liq}\) and aspect \(r=\frac{L}{W}\): \(A=\frac{V_\mathrm{w}}{D_\mathrm{liq}}\), \(W=\sqrt{\frac{A}{r}}\), \(L=rW\). Total depth \(D = D_\mathrm{liq} + \text{freeboard}\).
  6. Materials are then estimated from external dimensions (thicknesses) → RCC, rebar, excavation, pipes, covers, and **cost**.

Tip: The widget also supports Reverse mode — give known tank dimensions and it back-calculates how many people it supports at your standard’s defaults.

How to use the tool

  1. Choose units (SI or Imperial) and select a standard. Defaults will auto-fill detention, lpcd/gpd and sludge rate values derived (verify locally).
  2. Add segments such as “Main house”, “Annexe”, or “School block” and enter people. You can tweak per-capita flow and peak factor.
  3. Set design depth, L:W ratio, and chambers. Press Calculate.
  4. Enter (or accept) your market’s unit rates for concrete, rebar, pipes, covers and excavation. Costs update instantly.
  5. Open the Methodology section to see formulas. Click Generate HTML Report for a printable one-pager with KPIs and a detailed table.

Worked Example — 4-Person Home (IS 2470, SI Units, India Market)

Assumptions: detention = 24 h, per-capita discharge = 120 lpcd, sludge = 77 L/person·year, desludging every 1 year, liquid depth = 1.2 m, freeboard = 0.3 m, L:W = 2.5, 2 chambers; walls = 200 mm, base = 150 mm, top = 120 mm, partition = 115 mm; pipe allowance = 10 m; rebar = 80 kg/m³. India rates: concrete ₹6000/m³, rebar ₹76/kg, 110 mm PVC ₹100/m, access cover ₹1500 each, excavation ₹400/m³.

Step-by-step hydraulics
Total people \(P\)4
Daily flow \(Q = P × 120\)480 L/d= 4 × 120
Liquid volume \(V_\mathrm{liq} = Q × \frac{24}{24}\)0.48 m³ (16.95 ft³)
Sludge storage \(V_\mathrm{s} = \frac{4 × 77 × 1}{1000}\)0.308 m³ (10.88 ft³)
Working volume \(V_\mathrm{w} = V_\mathrm{liq}+V_\mathrm{s}\)0.788 m³ (27.83 ft³)
Liquid depth \(D_\mathrm{liq}\)1.2 m
Plan area \(A=V_\mathrm{w}/D_\mathrm{liq}\)0.657 m²
With \(r=L/W=2.5\): \(W=\sqrt{A/r}\), \(L=rW\) W = 0.513 m (1.681 ft), L = 1.281 m (4.204 ft) Calculated geometry
Total internal depth \(D = 1.2 + 0.3\)1.5 m (4.921 ft)

Code check: IS 2470 suggests minimum internal width 750 mm. Our calculated width (0.513 m) is less. A practical, compliant adoption is W = 0.75 m, L = 1.875 m (keeping L:W=2.5). This oversizes the tank (safe) — see “Recommended dimensions” below.

Structural quantities & costs (calculated geometry)
RCC volume2.041 m³ (72.09 ft³)
Rebar mass163.3 kg
Excavation6.383 m³ (225.43 ft³)
Grand cost (₹)₹36,049
ItemQuantityRateAmount
Concrete (RCC)2.041 m³₹ 6,000/m³₹ 12,247
Rebar163.3 kg₹ 76/kg₹ 12,411
110 mm PVC pipe10 m (allowance)₹ 100/m₹ 1,000
Access covers2 each₹ 1,500/each₹ 3,000
Excavation6.383 m³₹ 400/m³₹ 2,553
Subtotal₹ 31,211
+ 10% markup, + 5% contingency₹ 4,838
Grand Total₹ 36,049

External dims for this case: L×W×D = 1.681 × 0.913 × 1.65 m.

Recommended dimensions (meet IS min width 0.75 m)

Adopt W = 0.75 m, L = 1.875 m, D = 1.5 m. This increases safety margin and working volume.

Working volume (new)1.996 m³ (70.47 ft³)
RCC volume2.865 m³ (101.17 ft³)
Rebar mass229.2 kg
Grand cost (₹)₹48,892

External dims ≈ 2.275 × 1.15 × 1.65 m. Excavation ~ 9.308 m³. Costs recomputed with the same market rates.

Want to compare with a different market or Imperial units? Switch the widget to USD or GBP and toggle Imperial — all KPIs, dimensions and cost units update live.

Design tips

  • Check local by-laws for setbacks, groundwater, watertable, ventilation and soakaway/percolation requirements.
  • Adopt the **min internal width** from your standard even if math suggests smaller; longer, narrower tanks aid settling.
  • Use our related tools to plan the job end-to-end: earthwork, concrete & mixes, rebar/BBS, and pipe hydraulics.

Always verify against your local standard and soil percolation test results.